This device is a digital USB ammeter that allows you to measure current automatically. It can provide quite accurate digital measures (2 mA, 1%). It works with direct current (DC) as well as alternating current (AC) for which it provides the RMS value (5 mA or 3%).
This device is isolated, which means that the sensor part is electrically disconnected from the USB part: you can measure any current including one coming from the mains, without risk of frying your computer.
The module provides immediate reading on USB, and can also store measures on the device internal flash for later retrieval when connected again by USB.
This device can be connected directly to an Ethernet network using a YoctoHub-Ethernet, to a WiFi network using a YoctoHub-Wireless-n and to a GSM network using a YoctoHub-GSM.
USB cables and enclosures to be ordered separately.
Specifications1
Hardware release:Rev. CProduct ID:YAMPMK01
Product name:Yocto-Amp
USB connector:micro-B
Width:20mm
Length:56mm
Weight:10g
Max current (Cont.):10A DC/rms
Max current (peak):17A DC/rms
Refresh rate:10Hz
Input impedance:5mΩ
Max working voltage:250V r.m.s.
Accuracy (AC, 50Hz/60Hz):3 mA, 1%
Accuracy (DC):2 mA, 1%
Sensitivity:2 mA, 0.3%
Measurement category:Cat II
Protection class, according to IEC 61140:class II
USB isolation, clearance dist.:3mm
USB isolation, creepage dist.:3 / 6mm
USB isolation, dielectric strength (1 min.):3kV r.m.s.
Normal operating temperature:5...40Ѓ
Extended operating temperature2:-30...85Ѓ
Power derating:0.5A/Ѓ above 67Ѓ
Supported Operating Systems:Windows (PC + IoT), Linux (Intel + ARM), macOS, Android
Drivers:Driverless, no driver needed
API / SDK / Libraries:C++ Obj-C C# VB.NET UWP Delphi Python Java Android LabVIEW
API / SDK / Libraries (TCP only):Javascript Node.js PHP
RoHS compliance:RoHS III (2011/65/UE+2015/863)
Suggested enclosure:YoctoBox-Long-Thick-Black-Vents
Harmonized tariff code:9032.9000
Made in:Switzerland
1 These specifications are for the current hardware revision. Specifications for earlier revisions may differ.
2 The extended temperature range is defined based on components specifications and has been tested during a limited duration (1h). When using the device in harsh environments for a long period of time, we strongly advise to run extensive tests before going to production.